ログイン 会員登録
icon_bulk_order一括注文 Acrobiosystems for English
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0-9
phone
Your Position: ホーム > Kits > Capsid protein p24 > RES-A050

resDetect™ HIV-1 p24 ELISA Kit (Residue Testing)

For research use only.
    Product Specifications
    Assay TypeSandwich-ELISA
    AnalyteCapsid protein p24
    Format96T (8×12 strips)
    ReactivityHIV (HV1-HXB2)
    Regulatory StatusRUO
    Sensitivity<7.81pg/mL
    Standard Curve Range250-7.81pg/mL
    Assay Time3 hr 20 min
    Suitable Sample TypeFor the quantitative determination of HIV-1 p24 in Cell Culture Supernatants, Plasma, Serum.
    Sample volume100 μL
  • Product Overview
    resDetect™ HIV-1 p24 ELISA Kit (Residue Testing) is based on the ELISA sandwich method and is used for the quantitative detection of Human Immunodeficiency Virus-1 p24 (HIV-1 p24) in samples from CAR-T product preparation processes where it is used as a lentivirus vector. It is designed to provide a reliable solution for CAR-T product quality assessment during drug development and CMC quality control stages.
  • Reconstitution
    Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.
  • Storage
    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

    Materials Provided
    IDComponentsSize
    RES050-C01Pre-coated Anti-HIV-1 p24 Antibody Microplate1 plate (8×12 strips)
    RES050-C02HIV-1 p24 Standard20 μg
    RES050-C03Biotin-Anti-HIV-1 p24 Antibody20 μg
    RES050-C04Streptavidin-HRP50 μL
    RES050-C0510xWashing Buffer 50 mL
    RES050-C062xDilution Buffer50 mL
    RES050-C07Substrate Solution12 mL
    RES050-C08Stop Solution7 mL
    RES050-C091xLysis Buffer12 mL
Typical Data Please refer to DS document for the assay protocol.
 Capsid protein p24 TYPICAL DATA

For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

  • Clinical and Translational Updates

コメント (0)


ETD of in-stock products: 4 business days

価格(USD) : 360.00

プロモーション&展示



データシート&ドキュメンテーション

DMF請求
DMF (Drug Master File)

関連製品一覧

新製品

お問い合わせ&コメント

This web search service is supported by Google Inc.